10A-PPS 7Z07904 Laser Measurement Sensor

Updated:2025-03-13

Views:2936

  • Brand: OPHIR
  • Model: 10A-PPS
  • Description: The BeamTrack series 10A-PPS laser measurement sensor measures laser beam size and position well as power and energy. It has a 16mm aperture and can measure beam size to 5% accuracy and position to 0.
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

Overview of 10A-PPS laser measurement sensor:

The BeamTrack series 10A-PPS laser measurement sensor measures laser beam size and position well as power and energy. It has a 16mm aperture and can measure beam size to 5% accuracy and position to 0.1mm accuracy. It measures power from 20mW to 10W and energy from 6mJ to 2J. The sensor comes with a 1.5m cable that connects it to the electronic box, and another 0.5m cable that connects the box to a Meter or PC interface.

10A-PPS Sensor Drawing:

Main parameters:

Absorber Type Broadband
Aperture ?16mm
Spectral Range 0.19 - 20μm
Power Range 20mW-10W
Energy Range 6mJ-2J
Dimensions ?65 W x 34 D (mm)
Max Pulse Energy 2J
Max Average Power Density 28kW/cm2
Response Time 0.8 s
Max Energy Density (for <100ns) 0.3J/cm2
Max Energy Density (for 2ms) 2J/cm2
Max Average Power 10W

Problem summary:

When using the BeamTrack sensor with StarLab on a PC, can StarLab be used to record position and size data? What is the sampling rate?

StarLab can record the beam position. The power measurement value of Ophir power sensor is recorded 15 times per second. When the BeamTrack sensor is connected to StarLab through Juno, the position/size measurement value is also recorded 15 times per second. When the BeamTrack sensor is connected to the StarLab via the Vegas/Nova II, the position/size measurements are recorded once per second. This is because in Vega/Nova II, the sampling speed for these parameters is slow.

Can the BeamTrack sensor be used to measure the position and size of the pulsed laser?

Because position and size are measured together with power, if the laser pulses at a rate at which the average power can be measured, then position and size can also be measured.

For what type of laser points, the BeamTrack sensor can be used to measure the position and size?

The BeamTrack sensor can measure the position of any beam shape. Only the size of the Gaussian (TEM00) beam can measure the specified accuracy. For other laser modes, the size measurement is relative.

Must a specific sensor be used only with the instrument used when ordering?

Ophir instruments and sensors are calibrated independently. Each instrument has the same sensitivity as the other instrument, and the error is about 2%. Each sensor is calibrated independently of a specific instrument, and its calibration information is contained in the DB15 plug. When the sensor is connected to the instrument, the instrument will read and interpret this information. Since the accuracy of the sensor is usually+/- 3%, the additional 0.2% error that may result from inserting different instruments can be ignored, so it does not matter which calibration instrument is used for a specific calibrated sensor.

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@www.jidi9.com
主站蜘蛛池模板: 欧美精品一区二区性色a v| 国产精品久久久久久久av电影| 国产精品乱码视频| 亚洲日本欧美在线| 国产成人精品在线播放| 欧美二区在线| 日本视频一区二区在线观看| 亚洲综合在线中文字幕| 国产精品老女人精品视频| 国产在线拍偷自揄拍精品| 久久久久北条麻妃免费看| 欧美亚洲另类激情另类| 日韩av免费一区| 日韩一区二区高清视频| 91精品国产一区| 91精品视频播放| 91高潮在线观看| 91国偷自产一区二区三区的观看方式| 国产精品国语对白| 成人国产精品久久久久久亚洲| 国产精品美女久久| 国产精品乱码视频| 99在线影院| 五月婷婷综合色| 日韩在线第三页| 欧美日韩一区二| 欧美亚洲国产精品| 九九精品视频在线| 国产精品亚洲a| 97成人精品视频在线观看| 97欧美精品一区二区三区| 亚洲国产一区二区三区在线播 | 欧美在线亚洲在线| 欧美在线视频二区| 美女精品视频一区| 国产又粗又爽又黄的视频| 国产精品久久久久久久午夜 | 日韩在线精品一区| 欧美中文字幕精品| 久久免费一级片| 国产精品偷伦免费视频观看的|