欧美国产亚洲另类动漫_在线观看不卡av_91精选在线观看_日韩精品资源二区在线

Products

current position:home page>Products>Measuring Instrument>Pulsar>

AVFM 6.1 Area Velocity Flow Meter

Updated:2025-03-13

Views:3262

  • Brand: Pulsar
  • Model: AVFM 6.1
  • Description: The Area Velocity Flow Measurement method is the most common method of all flow measurements. The AVFM 6.1 Area Velocity Flow Meter uses a submersible ultrasonic sensor measuring both the level and ve
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

AVFM 6.1 Area Velocity Flow Meter Description:

User's Manual Datasheet

The Area Velocity Flow Measurement method is the most common method of all flow measurements. The AVFM 6.1 Area Velocity Flow Meter uses a submersible ultrasonic sensor measuring both the level and velocity of flowing liquid to calculate flow measurement in an open channel or pipe. The sensors are mounted either inside a pipe or at the bottom of a channel, and the sensor is built to resist fouling, corrosion, and abrasion. The AVFM 6.1 Area Velocity Flow Meter can be configured with the standard submerged velocity-level sensor or with submerged velocity in combination with a separate non-contacting ultrasonic level sensor, which is suitable for highly aerated fluids or those with a high concentration of suspended solids.

The AVFM 6.1 can measure forward flow velocity up to 6 m/s (19.7 ft/s) and reverse flow up to 1.5 m/s (5 ft/s). The electronics and software sample and average flow rates continuously provide stable readings. The submerged velocity/level sensor will measure flow in partially full and surcharged pipes with pressure up to 10 psi. The minimum recommended pipe diameter for the AVFM 6.1 Area-Velocity Flow Meter is 150 mm (5.9 in).

Configuration is simple for the AVFM 6.1 Area Velocity Flow Meter. Just enter the pipe diameter or channel dimensions and the AVFM 6.1 automatically computes and displays flow volume. Configure the AVFM 6.1 for installation in irregular or compound channel shapes by entering the channel width and multiple level points through the simple menu system. Channels for virtually any shape can be monitored with your choice of measurement units.

The Flow Meter will store time and date-stamped flow values at 10-second to 6-minute intervals. Daily flow reports are automatically created where total, minimum, maximum, and average flow rates are displayed on the LCD display. Transfer log files and daily flow reports to any USB flash drive by connecting to the logger’s USB output.

The AVFM 6.1 Area Velocity Flow Meter is suitable for open channel measurement applications such as influent flow monitoring, effluent flow monitoring, wastewater, stormwater, industrial wastewater applications, and irrigation water flow measurement. Its easy-to-use, menu-driven setup means that the AVFM 6.1 Area-Velocity Flow Meter is just minutes away from giving you that all-important flow measurement result.

Features

No flume or weir required – submersible ultrasonic sensor measures velocity and level simultaneously to calculate flow. No moving parts to wear, foul, or clog.

The built-in 5-button keypad, intuitive menu, and large backlit LCD display make the AVFM 6.1 the most operator-friendly area-velocity flow meter on the market.

Fast, simple, installation and set-up.

Improved performance in a wider range of operating conditions.

At a glance, view flow rate, velocity, level, totalizer, relay status, and important diagnostic information on the LCD display.

Three isolated 4-20 mA outputs for flow rate, velocity, and level, and two relay outputs for pulse output or alarm.

6.5 million point data logger for greater flexibility of data monitoring, control, and reporting.

Min, Max, and Total Flow data from the last 365 days is available on the LCD display, or download directly to a USB for easy reporting.

Monitors flow rate, volume total, run hours, and diagnostic information through only two wires with the optional Modbus RTU serial communication output.

Specifications

General Specifications
Spec name: Description:
Channel Types Round pipe, rectangular, trapezoid, egg, or custom shapes
Electronics Enclosure NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
Accuracy Level: ±0.25% of reading or ±0.08 in, whichever is greater. Repeatability & Linearity 0.1%.
Velocity: ±2% of reading or ±0.012 m/s (0.04 ft/s), whichever is greater. Requires solids or bubbles minimum size of 100 microns, minimum concentration 75 ppm. Repeatability & Linearity 0.5%
Display White, back-lit matrix - displays flow rate, totalizer, relay states, operating mode, and calibration menu
Programming Built-in 5-key calibrator with English, French, or Spanish language selection
Power Input 100-240 V AC 50/60 Hz, 10 VA maximum.
Optional: 9-32 V DC, 10 W maximum
Outputs 3 Isolated 4-20 mA, 1000 ohm, (Flow, Level, and Velocity) or 0-5 V DC by menu selection
Control Relays 2 Relays, form 'C' dry contacts rated 5 amp SPDT; programmable for flow proportional pulse (sampler/totalizer), flow, and/or level alarm
Data Logging Programmable 26 million point data capacity, time and date stamped plus formatted flow reports including Total, Average, Minimum, Maximum, and times of occurrence. Includes USB output to Flash Drives and Windows software
Operating Temperature (Electronics): -20 °C to 60 °C (-5 °F to 140 °F)
Approximate Shipping Weight 4.5 kg (10 lbs)
QZ02L Sensor Specifications
Spec name: Description:
Velocity Measurement Range 0.031 m/s to 6.2 m/s (0.1 ft/s to 20 ft/s) and reverse flow to -1.5 m/s (-5 ft/s) in fluids containing bubbles or solids with a minimum size of 100 microns and a minimum concentration of 75 ppm to act as acoustic reflectors
Level Measurement Range Minimum Head: 25.4 mm (1 in). Maximum Head: 4.57 m (15 ft)
Operating Temperature -15 °C to 80 °C (5 °F to 175 °F)
Exposed Materials 316 stainless steel, epoxy resin, polyurethane
Sensor Cable 7.6 m (25 ft) submersible polyurethane jacket, shielded, 3-coaxial
Sensor Mounting Includes MB-QZ stainless steel mounting bracket
Temperature Compensation Automatic, continuous

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@www.jidi9.com
主站蜘蛛池模板: 国产精品1234| 欧美日韩高清免费| 国产精品自拍首页| 日韩在线视频线视频免费网站| 免费久久99精品国产自| 91精品国产91久久久久久久久 | 极品日韩久久| 欧美激情综合色综合啪啪五月| av中文字幕av| 高清国产一区| 国产精品乱码视频| 国产精品美女黄网| 国产精品我不卡| 国产日韩欧美在线视频观看| 久久全国免费视频| 久久久91精品| 国产日韩欧美成人| 国产精品亚洲a| 国产精品成人播放| av不卡在线免费观看| 中文视频一区视频二区视频三区 | 日韩精品视频在线观看视频| 亚洲精品一区二区三| 亚洲爆乳无码专区| 日韩在线不卡视频| 欧美一区二区三区免费观看| 欧美成人在线影院| 狠狠色伊人亚洲综合网站色| 九九久久九九久久| 国产日韩欧美夫妻视频在线观看| 精品少妇在线视频| 国产在线观看精品一区二区三区| 国产精品人成电影在线观看| 国产精品美女av| 亚洲精品免费av| 深夜福利一区二区| 欧洲精品亚洲精品| 精品无码久久久久久久动漫| 国产又粗又爽又黄的视频| 久久99精品久久久久久噜噜| 国产精品毛片一区视频|