BeamPeek? system

Updated:2025-03-13

Views:2866

Product Details

Functional features of the BeamPeek? system:

User 's Manual

The BeamPeek? integrates a laser beam profiler camera, power meter, beam dump, beam splitters, and optics to provide an all inclusive solution for additive manufacturing laser analysis in an industrial environment.

  1. Focal spot size

  2. Focal spot position calibrated to build plane

  3. Laser power

  4. Laser power density

  5. Changes in spot size & power over time

The BeamPeek allows up to 2 minutes of continuous measurement at 1kW with passive cooling, without any need for a fan or water/air chilling through a beam dump interchangeable cartridge. Its industrial design makes it easy to integrate into production lines and perform analysis of laser properties without interference with the production process.

Drawings of the BeamPeek? system:

BeamPeek? System Specifications:

Beam Profiling
Wavelengths 532nm, 1030-1080nm
Min-Max Focus Spot Size 34.5μm - 2mm
Power Range 10 - 1000 Watts
Focal Length 150mm-800mm
Focal spot position calibrated ±100μm
Beam Profiling ISO 11146 Measurements
Power Meter NIST traceable calibration ±3%
Compliance CE, UKCA, China RoHS

BeamPeek? System FAQ

Is a periodical calibration required for the BP?

Yes, since the BeamPeek includes Ophir regular Power Meter.

Where is the Camera sensor/Focal plane positioned?

Unlike the BeamCheck that has the focal plane set so that the camera sensor is in focus when laser focus is positioned at bed surface, the BeamPeek camera sensor is approximate 75mm (the exact value is calibrated individually for each device) over the base/machine bed. To get the beam focus on camera sensor the machine bed must move down the by the calibrated value. The reason for this setup is improved power handling: higher maximum power and longer exposure time to high power.

What is the minimum waiting time to get power measurements results?

Minimum response time for power measurements is 3 seconds, as for power meters with thermal head.

IF power is higher value or longer exposure time than maximum allowed will the BeemPeek suffer heavy damage? How would I know if the device is damaged?

The BeamPeek is designed with some spare regarding overload, power or exposure time; if the recommended values were overpassed there are simple visual inspection besides the functional test that customer can perform: removal of Beam Dump tray, checking cleanliness of the protective window (can be removed and cleaned of outgassing due to very high power density or too long exposure), remove and inspect the diffusing interchangeable lens and looking thru the system aperture with lens removed to verify optics integrity in case of too high power.

If NIR laser wavelength 1070nm is used, which PM wavelength should be selected for measurements 1064nm or 1080nm?

Select the wavelength which is closest to laser wavelength, in this case 1064 is closer than 1080.

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@www.jidi9.com
主站蜘蛛池模板: 久久99热精品这里久久精品| 美女av一区二区三区| 亚洲v日韩v欧美v综合| 蜜桃视频成人在线观看| 国产精品69av| 久久riav| 久久久久久午夜| 日韩精品福利视频| 99视频免费观看蜜桃视频| 精品国偷自产在线视频| 麻豆久久久9性大片| 蜜桃av噜噜一区二区三区| 欧美在线视频一区二区| 91精品中文在线| www国产亚洲精品| 国产精品高潮在线| 国产精品国内视频| 国产精品美女免费| 国产精品网红直播| 国产精品久久久久久久久久东京 | 久久99国产综合精品女同| 欧美不卡视频一区发布| 欧美一区二区三区精品电影| 日韩免费观看视频| 日本一区二区在线视频| 欧美日韩精品综合| 久久久中文字幕| 精品99在线视频| 国产精品久久久久久av福利| 国产日韩欧美黄色| 国产精品裸体一区二区三区| 丁香六月激情网| 亚洲欧洲精品一区| 日韩美女视频中文字幕| 蜜桃视频一区二区在线观看 | 亚洲一区二区免费| 午夜精品理论片| 欧美日韩国产第一页| 久久精品久久精品国产大片| 国产精品永久免费在线| 在线精品日韩|